Rolling test: using the mattress rolling test machine, take the product filled with saturated gas, place the 150KG roller in the middle of theflocking top, and cycle back and forth for 3000 times. It is required that the melting surface of the product is not broken, flocking does not fall off,and does not explode.Therefore, air mattress Only then will more and more pump owners cheer for it and spread the value and function of the brand. https://hongyusj-plastic.com
Inflate and deflate test: using an inflatable mattress performance testing machine, inflate the product to 0.6PSI (4127pa), hold pressure for 10 s, and cycle back and forth to 0.2PSI (1379pa) for 1000 times. It is required that the product should not be deformed and the bonding surface should not be broken
Static pressure test: use static pressure test sandbag, take the saturated product, put the relevant weight sandbag (small bed 145kg,big bed 270kg) directly above, static pressure for 8 hours, the product velvet surface does not break, and the air pressure > 0.2PSI (1379pa).
Tensile test: using a desktop tensile testing machine, take the product after blasting and cut the position of each joint, such as fabric and enclosure, fabric and pull tape, pull belt and pull belt, bottom material and wrap material, bottom material and pull belt, etc., the width is 1 inch,The tensile force is required to be > 9.5kg (test ambient temperature 25<C), and the fracture position is not allowed to appear at the solution interface.